Professional Sanicubic 2 Pro Engineer in Ireland

The Sanicubic 2 Pro is a powerful twin-pump lifting station for demanding black water and grey water applications where gravity drainage is not available.

It can receive wastewater from WCs, wash basins, sinks, showers, baths, bidets, washing machines and dishwashers when the complete installation is designed correctly.

Two high-performance macerating pumps operate alternately during normal use. Therefore, the system shares the workload between both motors and helps balance wear.

During periods of increased inflow, both pumps can operate together. In addition, the second pump can provide valuable continuity if one pumping system develops a fault.

This operating arrangement makes the Sanicubic 2 Pro suitable for busy commercial premises, public buildings and larger residential properties where wastewater removal is important to normal operation.

The standard Sanicubic 2 Pro uses a remote control box and a wireless alarm system. Its motors and level-control components are designed to remain accessible for professional servicing.

At Saniflo.Irish, we have serviced, repaired and replaced Sanicubic lifting stations since 2015.

As an Approved Saniflo Engineer authorised by SFA Saniflo, we specialise exclusively in Saniflo products.

Our experience helps us identify pump faults, control problems, blocked pipework and installation defects before recommending the most practical long-term solution.

Whether your Sanicubic 2 Pro needs preventative servicing, professional repairs or complete replacement, we can help.

Our aim is always to restore dependable operation while reducing unnecessary disruption to the property.

Common Sanicubic 2 Pro Problems

The Sanicubic 2 Pro is designed for demanding service. However, both pumps, the pneumatic level system, the control equipment and the connected pipework still require inspection and maintenance.

From our experience, many faults develop because unsuitable materials enter the lifting station or deposits gradually restrict the hydraulic system.

Wet wipes, sanitary products, cleaning cloths and other non-biodegradable materials can obstruct the macerating mechanism. In addition, grease, detergent residue, food particles and limescale may collect inside the tank or discharge pipework.

As restrictions increase, pumping cycles may become longer. Consequently, one or both motors can operate under unnecessary load.

Installation quality also affects long-term reliability. Incorrect discharge pipework, unsuitable bends, poor ventilation, restricted service access and incorrectly positioned valves can all make the system harder to maintain.

Common Symptoms We Repair

Some of the most common Sanicubic 2 Pro problems include:

  • One pump does not operate
  • Both pumps fail to start
  • Pumps run continuously
  • High-level alarm activates
  • Wireless alarm sounds
  • Control box reports a fault
  • Slow pumping performance
  • Water backs up into connected appliances
  • Blocked macerating mechanism
  • Restricted discharge pipe
  • Non-return valve failure
  • Frequent cycling
  • Internal leaks
  • Electrical faults
  • Unusual motor noise
  • Bad odours

Every repair starts with a complete diagnosis of the lifting station and the surrounding installation.

First, we identify the cause. Then, we explain the most suitable repair option and any preventative improvements.

Common Faults We Repair

Customers often contact us after searching for one of the following Sanicubic 2 Pro problems:

  • Sanicubic 2 Pro not pumping
  • Sanicubic 2 Pro alarm sounding
  • One Sanicubic 2 Pro motor not working
  • Sanicubic 2 Pro keeps running
  • Sanicubic 2 Pro blocked
  • Sanicubic 2 Pro leaking
  • Sanicubic 2 Pro control box fault
  • Sanicubic 2 Pro wireless alarm fault
  • Duplex lifting station not alternating
  • Commercial sewage lifting station blocked
  • Water backing up into toilets
  • Commercial wastewater pump repair

From Our Experience

The Sanicubic 2 Pro provides a valuable level of operational protection because it uses two independent pumping systems.

During normal operation, automatic alternation distributes the workload between both motors. During higher inflow, both pumps can run together to increase pumping capacity.

However, a twin-pump system should not be treated as maintenance-free. If one motor develops a fault and the problem remains unnoticed, the installation may continue operating on the second pump without its normal backup protection.

For this reason, alarm warnings, unusual pumping patterns and changes in operating noise should be investigated promptly.

We inspect the complete system rather than replacing parts without identifying the cause of failure. In many cases, a worn service component, a blocked non-return valve or a restricted discharge route can be corrected without replacing the lifting station.

Our approach remains the same for every Saniflo installation: repair first and replace only when replacement offers better long-term value.

Annual Sanicubic 2 Pro Servicing

Regular servicing helps protect both pumping systems and reduces the risk of unexpected wastewater disruption.

Because operating conditions vary, the maintenance interval should reflect the number of connected appliances, wastewater volume and importance of the installation.

What We Check During a Service

During a professional service, we inspect both macerating pumps, motor assemblies and accessible internal components.

We check the pneumatic level-control system, remote control box, wireless alarm, electrical connections, seals, non-return valves and accessible isolation valves.

Next, we inspect the tank for unsuitable materials, grease, detergent residue, limescale and other deposits that may reduce efficiency.

We then test automatic pump alternation, individual pump operation and simultaneous operation where appropriate.

In addition, we examine the accessible discharge pipework, ventilation arrangement and service access. Where a Building Management System connection is used, its interface should also be considered during system testing.

Early inspection can identify developing faults before both pumping systems are affected. As a result, preventative maintenance may reduce emergency repairs and business downtime.

Optional Deep Steam Cleaning

For a higher level of preventative maintenance, we offer optional Deep Steam Cleaning for an additional €60.

High-temperature steam helps remove grease, bacteria, biofilm, soap residue, limescale and unpleasant odours without harsh chemicals.

This additional cleaning can be useful where commercial operating conditions allow deposits to develop more quickly.

Sanicubic 2 Pro Repairs

Most Sanicubic 2 Pro faults do not automatically require complete replacement. Therefore, every repair begins with professional diagnosis.

First, we test both pumps individually. We then check automatic alternation, simultaneous operation, pneumatic activation and the remote control equipment.

Depending on the fault, repairs may involve motors, macerating components, capacitors, seals, non-return valves, level-control parts, electrical components or alarm equipment.

Where appropriate, we use genuine Saniflo replacement parts.

Because the Sanicubic 2 Pro has two pumps, one operating motor may temporarily mask a fault with the second system. Consequently, we test both pumping channels rather than confirming only that wastewater leaves the tank.

We also inspect the surrounding pipework. A repeated motor fault may be linked to a restricted discharge route, unsuitable valve arrangement or another installation problem.

After completing the repair, we test the automatic operating cycle, pump alternation and alarm functions before returning the lifting station to service.

Sanicubic 2 Pro Replacement

Repair often provides the most economical solution, especially when the tank and one or both main pumping assemblies remain serviceable.

However, replacement may offer better long-term value when the installation has extensive internal wear, repeated major electrical faults or deterioration across both pumping systems.

Our replacement service includes removing the existing lifting station and installing a suitable genuine SFA Saniflo replacement.

Before recommending a new unit, we confirm the exact model and generation. The standard Sanicubic 2 Pro, Sanicubic 2 Pro Smart and Smart Brushless versions use different control arrangements and must not be treated as identical products.

We inspect the inlet connections, 50 mm discharge, ventilation, electrical supply, alarm arrangement, valves and available service space.

Finally, we test both pumps, automatic alternation, high-inflow operation and the complete alarm system.

Correcting installation problems during replacement can improve reliability and reduce future maintenance costs.

Our online Quick Quote calculator provides an estimated replacement price for a standard installation. Where additional installation work is required, we explain the requirements and costs before work begins.

Ideal Applications for the Sanicubic 2 Pro

The Sanicubic 2 Pro is designed for demanding installations that need to pump both black water and grey water where gravity drainage is unavailable.

Its twin-pump arrangement provides automatic alternation, additional capacity during high inflow and operational backup if one pumping system develops a fault.

Typical applications may include:

  • Busy commercial premises
  • Restaurants and hospitality premises
  • Hotels and guest accommodation
  • Office buildings
  • Retail premises
  • Public buildings
  • Education facilities
  • Care facilities
  • Leisure and sports facilities
  • Large residential properties
  • Apartment or mixed-use developments
  • Properties with several WCs and sanitary appliances

Final model selection should always consider expected inflow, peak demand, vertical lift, discharge route, wastewater temperature, ventilation and future service access.

The presence of two pumps does not remove the need for correct hydraulic design. Therefore, the complete installation should be assessed rather than selecting a lifting station from appliance count alone.

You can also explore our complete Saniflo Models guide to compare macerators, grey water pumps and lifting stations.

Technical Specifications

The Sanicubic 2 Pro is a floor-standing twin-pump lifting station for black water and grey water from multiple sanitary appliances.

The following values refer to the standard Sanicubic 2 Pro shown on the current SFA Saniflo Ireland product page. They should not be mixed with specifications for the Pro Smart or Smart Brushless versions.

Official Technical Specifications

  • Suitable for black water and grey water
  • Number of pumps: 2
  • Dual-motor alternating operation
  • Both pumps can operate during high inflow
  • Number of inlets: 5
  • External inlet diameters: 40 mm, 50 mm, 100 mm and 110 mm
  • External discharge diameter: 50 mm
  • External ventilation diameter: 50 mm
  • Power consumption P1: 1,500 W per pump
  • Motor output P2: 1,050 W
  • Power supply: 220–240 V
  • Frequency: 50–60 Hz
  • Motor speed: 2,800 rpm
  • Maximum current: 13 A
  • Single-phase supply
  • Electrical class: Class I
  • Motor insulation class: Class F
  • Motor protection rating: IP68
  • Operating mode: S3 50%
  • Remote control box with 4 m station-to-control cable
  • Wireless alarm system
  • Maximum head: 13 metres
  • Maximum flow rate: 15 m³/h
  • Total tank volume: 45 litres
  • Usable tank volume: 17.5 litres
  • Start level: 140 mm
  • Stop level: 70 mm
  • Alarm level: 210 mm
  • Normal pumped-liquid temperature: 35°C
  • Maximum intermittent liquid temperature: 70°C for up to 5 minutes
  • Pneumatic level activation
  • Pro X K2 shredding-wheel system
  • Compatible with a Building Management System connection
  • Genuine SFA Saniflo product
  • Designed, manufactured and tested in France

For current manufacturer information, view the official Sanicubic 2 Pro product page on the SFA Saniflo Ireland website.

Our Professional Recommendation

The Sanicubic 2 Pro has a 50 mm external discharge connection. Therefore, we recommend maintaining correctly installed 50 mm discharge pipework throughout the route unless a complete hydraulic assessment specifies otherwise.

The discharge must not be reduced below the manufacturer’s specified outlet size.

Discharge Route and Valves

The discharge route should remain as direct as practical and avoid unnecessary changes of direction.

Correct pipe support, suitable bends and accessible isolation arrangements help the system operate efficiently and simplify future maintenance.

Each pump relies on the complete discharge system. Consequently, a restriction after the lifting station can affect both pumping channels.

Ventilation and Service Access

The 50 mm ventilation connection should be installed in accordance with the manufacturer’s instructions and applicable drainage requirements.

The lifting station, motors, pneumatic level components, control box and valves must remain accessible for inspection and repair.

Placing permanent furniture, storage or fixed building work around the unit can increase labour time and business disruption.

Alarm and Control Equipment

The remote control box and wireless alarm should be installed where warnings can be recognised and acted upon promptly.

An alarm is an early warning, not a repair. Therefore, wastewater use should be reduced and the cause investigated whenever a fault or high-level warning occurs.

These recommendations reflect our practical experience with Saniflo lifting stations since 2015.

Typical Lifespan of a Sanicubic 2 Pro

A professionally installed and regularly maintained Sanicubic 2 Pro can provide many years of dependable service.

However, there is no single lifespan that applies to every lifting station.

Actual service life depends on operating frequency, wastewater volume, unsuitable materials, discharge conditions, installation quality and maintenance history.

The two pumps alternate during normal operation, which helps distribute operating time. Nevertheless, each motor, macerating assembly, seal, valve and electrical component remains subject to wear.

The tank may remain serviceable for longer than individual pumping or control components. Therefore, the failure of one part does not automatically mean that the complete lifting station requires replacement.

Regular inspection helps identify abnormal running times, worn components, alarm faults and developing restrictions before they cause a major breakdown.

Where practical, service components can often be repaired or replaced individually.

From our experience, correct installation, suitable everyday use and planned maintenance provide the strongest foundation for reliable long-term operation.

How to Extend the Life of Your Sanicubic 2 Pro

Long-term reliability depends on correct installation, prompt attention to warning signs and preventative maintenance.

Use the System Correctly

The Sanicubic 2 Pro handles normal black water and grey water. However, it should not be used as a waste-disposal system.

To help protect the pumps, avoid allowing the following materials to enter the installation:

  • Wet wipes
  • Sanitary towels and tampons
  • Nappies
  • Cleaning cloths
  • Paper towels
  • Cotton buds
  • Dental floss
  • Large quantities of cooking grease
  • Food waste
  • Plastic packaging
  • Building materials
  • Paint residue
  • Metal objects
  • Any unsuitable non-biodegradable materials

Respond to Early Warning Signs

Do not ignore a control-box fault, wireless alarm, unusual noise, longer pumping cycle or change in pump alternation.

Early investigation may prevent a single-pump fault from developing into a complete loss of service.

Maintain Access and Arrange Servicing

Keep the lifting station, control equipment and valves accessible. In addition, arrange maintenance at intervals appropriate to the actual workload and importance of the installation.

Clear access allows faults to be diagnosed more efficiently and can reduce labour time during servicing or repairs.

Why Choose Saniflo.Irish?

Twin-pump lifting stations require specialist product knowledge and a complete understanding of their control, alarm and hydraulic systems.

At Saniflo.Irish, we specialise exclusively in Saniflo products.

As an Approved Saniflo Engineer authorised by SFA Saniflo, we have serviced, repaired and replaced Saniflo systems since 2015.

We work throughout Dublin and the surrounding counties.

Our experience helps us identify motor faults, pneumatic-control problems, electrical defects, pipework restrictions and installation issues.

Every visit begins with diagnosis. First, we inspect the lifting station. Then, we assess the surrounding installation and explain the most practical repair options.

We understand that commercial and multi-occupancy properties depend on reliable wastewater removal.

For this reason, we focus on efficient repairs, honest advice, transparent pricing and practical long-term solutions.

Request Your Sanicubic 2 Pro Quote

Whether your Sanicubic 2 Pro needs preventative servicing, professional repair or complete replacement, we are ready to help.

Our online Quick Quote calculator provides an estimated price for many popular services.

Simply select the service you need and submit your enquiry. Afterwards, we will review the details and contact you to arrange a suitable appointment.

If you are unsure whether to repair or replace your Sanicubic 2 Pro, we can inspect the existing lifting station and provide honest advice based on its condition.

In many cases, maintenance or replacement of worn service components can restore reliable operation without unnecessary replacement.

Our objective is simple: keep the wastewater system operating efficiently while reducing unexpected breakdowns and disruption.

Get Your Sanicubic 2 Pro Estimate


    Sanicubic 2 Pro

    Sanicubic 2 Pro